Go to  Advanced Search

Aerobic treatment of a CTMP wastewater using a rotating biological contactor

Show full item record

Files in this item

Files Size Format Description   View
UBC_1991_A7 M38.pdf 11.01Mb Adobe Portable Document Format   View/Open
 
Title: Aerobic treatment of a CTMP wastewater using a rotating biological contactor
Author: Mathys, Renata Gabriela
Degree Master of Applied Science - MASc
Program Chemical and Biological Engineering
Copyright Date: 1991
Abstract: Effluents from high-yield TMP and CTMP mills contain biochemical oxygen demand and toxicity levels that are much higher than the effluents from low-yield kraft mills and if not properly treated before disposal can impose environmental threats to water bodies. Therefore, this study was undertaken to demonstrate the ability of a rotating biological contactor to remove organic matter from such a CTMP wastewater when operated at different flowrates and temperatures. An apparatus was constructed to allow for temperature control of the wastewater and the flexibility to change flowrates and disc rotational speed. Parameters studied included BOD₅, COD, suspended solids, dissolved oxygen, sulfur compounds, acetic acid and nutrient uptake. Because the lab device exposes a thin film of liquid to the air over an extensive surface, evaporation from the RBC as high as 87% at temperatures of ~ 30°C were experienced during the experiment. Results of this study showed that for hydraulic residence times (HRT) of 1 to 2 days the BOD₅ removal ranged from 77 to 86% with a corresponding COD removal of 63 to 72%. Increases in flowrate (decreases in HRT) resulted in a slight decrease in percent BOD (COD) removed and an increase in loading rate and BOD (COD) removal rate. An increase in temperature from 20 to 30°C increased BOD removal from 70.1 to 85% and COD removal from 45.8 to 71.4% at HRT=1.5 days. Dissolved oxygen, pH and MLVSS had no distinct effects on the removal of BOD₅ and COD. Losses due to evaporation of major volatile compounds tested were minimal at the pH of operation. Start-up time of the RBC was of the order of 1 day during the experiment. An attempt to do a run without microorganism activity by adding 50 mg/1 HgCl₂ failed to eliminate all the organisms present in the wastewater and RBC. Tracer studies revealed that the RBC was close to being perfectly mixed.
URI: http://hdl.handle.net/2429/30025
Series/Report no. UBC Retrospective Theses Digitization Project [http://www.library.ubc.ca/archives/retro_theses/]
Scholarly Level: Graduate

This item appears in the following Collection(s)

Show full item record

All items in cIRcle are protected by copyright, with all rights reserved.

UBC Library
1961 East Mall
Vancouver, B.C.
Canada V6T 1Z1
Tel: 604-822-6375
Fax: 604-822-3893