Go to  Advanced Search

Performance of shear stud clusters for precast concrete bridge deck panels

Show full item record

Files in this item

Files Size Format Description   View
ubc_2007-0151a.pdf 15.21Mb Adobe Portable Document Format   View/Open
 
Title: Performance of shear stud clusters for precast concrete bridge deck panels
Author: Larose, Kent Evan
Degree Master of Applied Science - MASc
Program Civil Engineering
Copyright Date: 2006
Abstract: The current edition of the Canadian Highway Bridge Design Code (CHBDC), CAN/CSA-S6-00 provides limited guidance for the design of composite bridges with precast concrete deck panels and steel girders. The shear connection is critical in determining the overall performance of the composite superstructure and is commonly achieved with a grout blockout in a precast concrete deck panel, which accepts a cluster of tightly spaced steel shear studs. No specific equations are found in the CHBDC for the design of shear studs used in this system. Furthermore, the current longitudinal spacing limitation of 600 mm for shear studs in the CHBDC is not conducive to the construction of precast concrete decks where an increased spacing of the stud cluster is desirable. An experimental testing regime was completed using push-test specimens constructed with precast concrete panels connected to steel flanges with steel studs within a circular grout pocket. Specimens were tested to failure to determine the ultimate capacity of a stud cluster and to investigate the reduction in ultimate strength after exposure to a number of loading cycles. A 36 m simple span composite superstructure was designed to the CHBDC. A parametric study was conducted on the spacing of stud clusters to investigate the serviceability limit state of the composite superstructure using data captured from the push test specimens. Experiments show that clustered shear studs embedded in high strength grout for construction using precast deck panels meet CHBDC strength requirements and that exceeding the code maximum stud spacing of 600 mm by a factor of two will not result in excessive displacements.
URI: http://hdl.handle.net/2429/31661
Series/Report no. UBC Retrospective Theses Digitization Project [http://www.library.ubc.ca/archives/retro_theses/]
Scholarly Level: Graduate

This item appears in the following Collection(s)