350-GHz high-resolution high-sensitivity passive video imaging system. Halpern, Mark
Abstract
We are developing a 350 GHz cryogenic passive video imaging system. This demonstration system uses 800 photon-noise-limited superconducting transition edge sensor bolometers. It will image a 1 m x 1 m area at a standoff distance of 16 m to a resolution of approximately 1 cm at video frame rates (20 frames per second). High spatial resolution is achieved by the use of an f/2.0 Cassegrain optical system with 1.3 m primary mirror. Preliminary testing of prototype detectors indicates that we can achieve a noise equivalent temperature difference (NETD) of 70 mK for the fully sampled 1 m × 1 m image at 20 frames per second. Copyright 2010 Society of Photo-Optical Instrumentation Engineers. One print or electronic copy may be made for personal use only. Systematic reproduction and distribution, duplication of any material in this paper for a fee or for commercial purposes, or modification of the content of the paper are prohibited.
Item Metadata
Title |
350-GHz high-resolution high-sensitivity passive video imaging system.
|
Creator | |
Publisher |
Society of Photo-Optical Instrumentation Engineers (SPIE)
|
Date Issued |
2010
|
Description |
We are developing a 350 GHz cryogenic passive video imaging system. This demonstration system uses 800 photon-noise-limited superconducting transition edge
sensor bolometers. It will image a 1 m x 1 m area at a standoff distance of 16 m to a resolution of approximately 1 cm at video frame rates (20 frames per second).
High spatial resolution is achieved by the use of an f/2.0 Cassegrain optical system with 1.3 m primary mirror. Preliminary testing of prototype detectors
indicates that we can achieve a noise equivalent temperature difference (NETD) of 70 mK for the fully sampled 1 m × 1 m image at 20 frames per second.
Copyright 2010 Society of Photo-Optical Instrumentation Engineers.
One print or electronic copy may be made for personal use only. Systematic reproduction and distribution,
duplication of any material in this paper for a fee or for commercial purposes, or modification of the content of the paper are prohibited.
|
Genre | |
Type | |
Language |
eng
|
Date Available |
2011-09-13
|
Provider |
Vancouver : University of British Columbia Library
|
Rights |
Attribution-NonCommercial-NoDerivatives 4.0 International
|
DOI |
10.14288/1.0107580
|
URI | |
Affiliation | |
Citation |
Becker, Daniel; Beall, James R.; Cho, Hsiao-Mei; Duncan, William D.; Hilton, Gene C.; Horansky, Robert D.; Irwin, Kent D.; Lowell, Peter; Niemack, Michael D.; Paulter, Nick; Reintsema, Carl D.; Schima, Frank; Schwall, Robert; Yoon, Ki Won; Ade, Peter A. R.; Tucker, Carole E.; Dicker, Simon R.; Halpern, Mark. 350-GHz high-resolution high-sensitivity passive video imaging system. Passive Millimeter-Wave Imaging Technology XIII, edited by David A. Wikner, Arttu R. Luukanen, Proceedings of SPIE Volume 7670, 76700M, 2010.
|
Publisher DOI |
10.1117/12.852932
|
Peer Review Status |
Reviewed
|
Scholarly Level |
Faculty
|
Copyright Holder |
Halpern, Mark
|
Rights URI | |
Aggregated Source Repository |
DSpace
|
Item Media
Item Citations and Data
Rights
Attribution-NonCommercial-NoDerivatives 4.0 International