Go to  Advanced Search

A microsphere based microfluidic check valve

Show full item record

Files in this item

Files Size Format Description   View
ubc_2011_fall_ou_kevin.pdf 3.868Mb Adobe Portable Document Format   View/Open
 
Title: A microsphere based microfluidic check valve
Author: Ou, Kevin
Degree Master of Applied Science - MASc
Program Mechanical Engineering
Copyright Date: 2011
Publicly Available in cIRcle 2011-09-14
Abstract: Biomedical applications of Micro-Electro-Mechanical System (MEMS) technology have sprung growth in the field of microfluidic systems and have been attracting much attention from scientific researchers and industry. Implantable drug delivery devices can deliver localized dosage which can reduce the side effects of medication. Such devices can maintain therapeutic concentrations of the drug over extended periods by providing small doses minimizing the risk of systemic toxicity. Recently, ocular drug delivery devices with micropumps using check valves have been demonstrated. The use of external magnetic actuation in a MEMS-based drug delivery device has been verified in reciprocating diaphragm micropumps. However, the magnetic diaphragm generates low pressures resulting in low flow rates (Re<1). This work investigates the use of polystyrene (PS) microspheres as resistive elements in a fluidic channel to create a check valve. The check valve takes advantage of the low profile microsphere and flow channel to rectify flow in low pressure and low flow applications. This makes the check valve ideal for thin planar reciprocating micropumps, which can be used as ocular drug delivery devices, with the conjunctival cul-de-sac being a possible site of implantation. The microspheres form a porous media which acts as variable fluid resistors based on the direction of flow, and also increases tortuosity in the check valve limiting diffusion from the device. Three check valve designs were characterized based on their flow rate and diodicity (ratio of flow in the forward and reverse direction). Pump performance, based on the check valves integrated in series with a deflecting diaphragm actuator, was investigated. Finally, a proof-of-concept diffusion study was conducted using docetaxel (DTX), a low aqueous solubility drug used to treat late stage proliferative retinopathy, as the sample drug to demonstrate the microsphere check valve’s ability to limit diffusion from the micropump.
URI: http://hdl.handle.net/2429/37310
Scholarly Level: Graduate

This item appears in the following Collection(s)

Show full item record

All items in cIRcle are protected by copyright, with all rights reserved.

Attribution-NonCommercial 2.5 Canada Except where otherwise noted, this item's license is described as Attribution-NonCommercial 2.5 Canada

UBC Library
1961 East Mall
Vancouver, B.C.
Canada V6T 1Z1
Tel: 604-822-6375
Fax: 604-822-3893