Wet-Bulb Temperature from Relative Humidity and Air Temperature. Stull, Roland B., 1950-
Abstract
An equation is presented for wet-bulb temperature as a function of air temperature and relative humidity at standard sea level pressure. It was found as an empirical fit using gene-expression programming. This equation is valid for relative humidities between 5% and 99% and for air temperatures between −20° and 50°C, except for situations having both low humidity and cold temperature. Over the valid range, errors in wet-bulb temperature range from −1° to +0.65°C, with mean absolute error of less than 0.3°C. Copyright 2011 American Meteorological Society (AMS). Permission to use figures, tables, and brief excerpts from this work in scientific and educational works is hereby granted provided that the source is acknowledged. Any use of material in this work that is determined to be “fair use” under Section 107 of the U.S. Copyright Act or that satisfies the conditions specified in Section 108 of the U.S. Copyright Act (17 USC §108, as revised by P.L. 94-553) does not require the AMS’s permission. Republication, systematic reproduction, posting in electronic form, such as on a web site or in a searchable database, or other uses of this material, except as exempted by the above statement, requires written permission or a license from the AMS. Additional details are provided in the AMS Copyright Policy, available on the AMS Web site located at (http://www.ametsoc.org/) or from the AMS at 617-227-2425 or copyright@ametsoc.org.
Item Metadata
Title |
Wet-Bulb Temperature from Relative Humidity and Air Temperature.
|
Creator | |
Publisher |
American Meteorological Society
|
Date Issued |
2011
|
Description |
An equation is presented for wet-bulb temperature as a function of air temperature and relative humidity at standard sea level pressure. It was found as an empirical fit using gene-expression programming. This equation is valid for relative humidities between 5% and 99% and for air temperatures between −20° and 50°C, except for situations having both low humidity and cold temperature. Over the valid range, errors in wet-bulb temperature range from −1° to +0.65°C, with mean absolute error of less than 0.3°C.
Copyright 2011 American Meteorological Society (AMS). Permission
to use figures, tables, and brief excerpts from this work in scientific and educational
works is hereby granted provided that the source is acknowledged. Any use of material in
this work that is determined to be “fair use” under Section 107 of the U.S. Copyright Act
or that satisfies the conditions specified in Section 108 of the U.S. Copyright Act (17
USC §108, as revised by P.L. 94-553) does not require the AMS’s permission.
Republication, systematic reproduction, posting in electronic form, such as on a web site
or in a searchable database, or other uses of this material, except as exempted by the
above statement, requires written permission or a license from the AMS. Additional
details are provided in the AMS Copyright Policy, available on the AMS Web site
located at (http://www.ametsoc.org/) or from the AMS at 617-227-2425 or
copyright@ametsoc.org.
|
Genre | |
Type | |
Language |
eng
|
Date Available |
2012-01-14
|
Provider |
Vancouver : University of British Columbia Library
|
Rights |
Attribution-NonCommercial-NoDerivatives 4.0 International
|
DOI |
10.14288/1.0041967
|
URI | |
Affiliation | |
Citation |
Stull, Roland B. 2011. Wet-Bulb Temperature from Relative Humidity and Air Temperature. Journal of Applied Meteorology and Climatology, 50 (11) 2267-2269
|
Publisher DOI |
10.1175/JAMC-D-11-0143.1
|