Oxidative pressure leaching of chalcocite by INCO Ltd.’s second stage leach process Saito, Benjamin
Abstract
The INCO Ltd. Copper Refinery Electrowinning Department (CRED) in Copper Cliff, Ontario, Canada, processes a Cu, Ni, Co, Fe, As, S and precious metals containing residue produced by the INCO Pressure Carbonyl (IPC) plant. This residue is treated in two successive leaching stages. The First Stage batch leach extracts most of the Ni, Co, Fe and As. During the Second Stage batch leach process, the oxidative pressure leaching of a predominantly Cu₂S feed is effected under acid deficient conditions. The main process objective is to preferentially extract the copper, leaving behind a residue rich in precious metals. Several physico-chemical parameters hinder the copper extraction by limiting oxygen mass transfer. Part I of this investigation focuses specifically on the impact of temperature and total arsenic content. Laboratory experiments were conducted at temperatures ranging from 100 to 135°C with different plant feed solids having arsenic concentrations ranging from 0.37 to 1.4 wt.%. Additional tests were performed with controlled arsenic additions to the feed electrolyte. The results showed that conditions of high temperature and high arsenic were detrimental to overall copper extraction rates. Suppression of leach kinetics was attributed to the formation of high viscosity basic copper sulphate slurries which inhibited oxygen mass transfer. High viscosity slurries resulted from the preferred precipitation of sub-micron acicular basic copper sulphate crystals over large platelet shaped crystals. The observed effects were believed attributable to two main factors: elevated supersaturation levels from increased initial rates of chalcocite leaching, and the formation of a heterogeneous nucleation substrate, possibly, basic copper arsenate, Cu₂As0₄(OH). In part II of this investigation, the oxygen mass transfer/mixing performance of the Second Stage leach process was examined. This was done in scaled-model tests (125 L). Improvements in surface aeration rates through changing impeller systems were sought. Results from the scaled model tests showed that converting from the current dual axial down-draft impeller system to a radial disk impeller system resulted in improvements in mass transfer rates by as high as 200% at 221 rpm. For a dual radial disk system, mass transfer rate increases came at the expense of significantly higher power draw. For a radial(top)/axial system, high mass transfer rates were achieved with only marginal power draw increase. Fill level sensitivity tests revealed that the axial impeller system was most sensitive to overfilling, resulting in near zero mass-transfer rates from only a +5% increase in fill height above the scaled normal fill height. Similar decreases in mass-transfer rates for both radial impeller systems came after +10% increase. Based on the test-work performed, the radial/axial system was judged to be the most successful in overall kLa and power draw performance. The internal cooling coil system was found to offer a partial baffling effect, sufficient to prevent gross swirling yet low enough prevent central vortex collapse. This condition was believed to be critical in achieving high gas-liquid mass transfer performance in the scaled model.
Item Metadata
Title |
Oxidative pressure leaching of chalcocite by INCO Ltd.’s second stage leach process
|
Creator | |
Publisher |
University of British Columbia
|
Date Issued |
1995
|
Description |
The INCO Ltd. Copper Refinery Electrowinning Department (CRED) in Copper Cliff,
Ontario, Canada, processes a Cu, Ni, Co, Fe, As, S and precious metals containing residue produced
by the INCO Pressure Carbonyl (IPC) plant. This residue is treated in two successive leaching
stages. The First Stage batch leach extracts most of the Ni, Co, Fe and As. During the Second Stage
batch leach process, the oxidative pressure leaching of a predominantly Cu₂S feed is effected under
acid deficient conditions. The main process objective is to preferentially extract the copper, leaving
behind a residue rich in precious metals. Several physico-chemical parameters hinder the copper
extraction by limiting oxygen mass transfer. Part I of this investigation focuses specifically on the
impact of temperature and total arsenic content.
Laboratory experiments were conducted at temperatures ranging from 100 to 135°C with
different plant feed solids having arsenic concentrations ranging from 0.37 to 1.4 wt.%. Additional
tests were performed with controlled arsenic additions to the feed electrolyte. The results showed
that conditions of high temperature and high arsenic were detrimental to overall copper extraction
rates. Suppression of leach kinetics was attributed to the formation of high viscosity basic copper
sulphate slurries which inhibited oxygen mass transfer. High viscosity slurries resulted from the
preferred precipitation of sub-micron acicular basic copper sulphate crystals over large platelet shaped
crystals. The observed effects were believed attributable to two main factors: elevated
supersaturation levels from increased initial rates of chalcocite leaching, and the formation of a
heterogeneous nucleation substrate, possibly, basic copper arsenate, Cu₂As0₄(OH).
In part II of this investigation, the oxygen mass transfer/mixing performance of the Second
Stage leach process was examined. This was done in scaled-model tests (125 L). Improvements
in surface aeration rates through changing impeller systems were sought. Results from the scaled
model tests showed that converting from the current dual axial down-draft impeller system to a radial
disk impeller system resulted in improvements in mass transfer rates by as high as 200% at 221 rpm.
For a dual radial disk system, mass transfer rate increases came at the expense of significantly
higher power draw. For a radial(top)/axial system, high mass transfer rates were achieved with only
marginal power draw increase. Fill level sensitivity tests revealed that the axial impeller system was most sensitive to overfilling, resulting in near zero mass-transfer rates from only a +5% increase in
fill height above the scaled normal fill height. Similar decreases in mass-transfer rates for both radial
impeller systems came after +10% increase. Based on the test-work performed, the radial/axial
system was judged to be the most successful in overall kLa and power draw performance.
The internal cooling coil system was found to offer a partial baffling effect, sufficient to
prevent gross swirling yet low enough prevent central vortex collapse. This condition was believed
to be critical in achieving high gas-liquid mass transfer performance in the scaled model.
|
Extent |
11189703 bytes
|
Genre | |
Type | |
File Format |
application/pdf
|
Language |
eng
|
Date Available |
2009-01-27
|
Provider |
Vancouver : University of British Columbia Library
|
Rights |
For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use.
|
DOI |
10.14288/1.0078514
|
URI | |
Degree | |
Program | |
Affiliation | |
Degree Grantor |
University of British Columbia
|
Graduation Date |
1995-11
|
Campus | |
Scholarly Level |
Graduate
|
Aggregated Source Repository |
DSpace
|
Item Media
Item Citations and Data
Rights
For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use.