Go to  Advanced Search

Objective monitoring of milk quality using a dynamic headspace gas chromatograph and computer-aided data processing

Show simple item record

dc.contributor.author Horimoto, Yasumi
dc.date.accessioned 2009-02-20
dc.date.available 2009-02-20
dc.date.copyright 1996 en
dc.date.issued 2009-02-20
dc.identifier.uri http://hdl.handle.net/2429/4839
dc.description.abstract This research was undertaken because of the need to develop an objective method for quality control of milk. A major problem in the dairy industry is off-flavour often found in milk. Quality control of milk is heavily dependent upon sensory evaluations supported by microbiological and chemical analyses. The chief purpose of this research was to demonstrate a simple and economical system for quality control of milk using a gas chromatogf aph and computer-aided data processing. Two experiments were conducted: one using microbial off-flavours and another using chemically induced off-flavours. First, Ultra High Temperature (UHT)-sterilized milk was inoculated with Pseudomonas fragi, Psuedomonas fluorescens, Lactococcus lactis, Enterobacter aerogenes, Bacillus subtilis and a mixed culture (L. lactis: E. aerogenes: P. fragi = 1:1:1) with approximately 10⁴ CFU mL⁻¹. The samples were stored at 4°C up to 10 days for P. fragi and P. fluorescens and at 30°C up to 24 hours for L. lactis, E. aerogenes, B. subtilis and the mixed culture. Several multivariate analyses were applied to the standaridized peak areas of GC data. A new multivariate analysis technique, principal component similarity analysis (PCS), was capable of classifying milk samples with regard to bacterial species and storage time. Artificial neural networks (ANN), partial least squares regression analysis and principal component regression analysis were also applied. ANN provided the most accurate means of classification. Secondly, pasteurized milk was treated to develop different off-flavours (lightinduced, oxidized, cooked and heated) according to the procedures of the American Dairy Science Association. The same pasteurized milk samples as those used for gas chromatographic analysis were used for sensory evaluation. Gas chromatography (GC) combined with PCS was more effective than sensory evaluation as a means of distinguishing milk samples. It was concluded that a combination of GC and chemometric methods may have great potential in evaluating the chemical and microbial quality of milk. en
dc.format.extent 5553175 bytes
dc.format.mimetype application/pdf
dc.language.iso eng en
dc.relation.ispartofseries UBC Retrospective Theses Digitization Project [http://www.library.ubc.ca/archives/retro_theses/]
dc.title Objective monitoring of milk quality using a dynamic headspace gas chromatograph and computer-aided data processing en
dc.type Electronic Thesis or Dissertation
dc.degree.name Doctor of Philosophy - PhD en
dc.degree.discipline Food Science en
dc.degree.grantor University of British Columbia
dc.date.graduation 1996-05 en
dc.degree.campus UBCV en


Files in this item

Files Size Format Description   View
ubc_1996-090957.pdf 5.553Mb Adobe Portable Document Format   View/Open
 

This item appears in the following Collection(s)

Show simple item record

All items in cIRcle are protected by copyright, with all rights reserved.

UBC Library
1961 East Mall
Vancouver, B.C.
Canada V6T 1Z1
Tel: 604-822-6375
Fax: 604-822-3893