Go to  Advanced Search

Identification and mitigation of high zinc discharges to the environment from the water diversion system at the Kemess South Mine

Show full item record

Files in this item

Files Size Format Description   View
2001 - Bent, Frostad, Davidson - Identification.pdf 670.7Kb Adobe Portable Document Format   View/Open
 
Title: Identification and mitigation of high zinc discharges to the environment from the water diversion system at the Kemess South Mine
Author: Bent, Harold; Frostad, Scott; Davidson, Scott Charles
Issue Date: 2001
Publicly Available in cIRcle 2009-06-10
Series/Report no. British Columbia Mine Reclamation Symposium 2001
Abstract: The Water Diversion System at Kemess Mine in north-central British Columbia was found to be releasing total zinc concentrations that exceeded the site water quality objective of 0.03 mg/L. The source of the zinc was determined to be sections of the buried diversion system constructed of galvanized steel. To mitigate this problem, the mine examined several options before deciding on the insertion of a smaller diameter Polyethylene pipe within the original conduit. The insertion of the Polyethylene pipe was completed in November 2000. Monitoring of water quality since the insertion has shown that the zinc water quality objective has been consistently met but for a few exceptions.
Affiliation: Applied Science, Faculty of